石油鉆桿短接絕緣涂層技術要求
2019-5-15 16:23:14 點擊:
1、絕緣件能要求:使用500V搖表測M絕緣值≥500Kohms。
1、Insulation requirements: measuring M insulation value 500Kohms with a 500V meter.
2、螺紋連接處可承受扭矩:45000N,絕緣涂層不破損。絕緣性能正常。
2、The threaded joint can withstand torque: 45000N, the insulation layer is not damaged.The insulation performance is normal.
3、外壁絕緣涂層有效距離要求:≥20mm,并且具有耐磨性。


3、Outer wall insulation coating effective distance requirements: 20mm, and wear resistance.
4、絕緣涂層涂覆耍求:內壁、外壁均噴涂。
4、Insulation coating coating: inner wall, outer wall are sprayed.
5、防水性能要求:螺紋連接處兩端設置防水裝置,防止打鉆用水進入螺紋處, 影響絕緣性能。
5、Waterproof performance requirements: both ends of the thread connection set waterproof device, prevent drilling water into the thread, affect the insulation performance.
6、絕緣短接使用壽命要求:井下循環時間不低于2000小時。
6、Insulation short life requirements: downhole cycle time not less than 2000 hours.
7、工具耐溫要求:可在200℃下連續使用。
7、Tools and heat-resistant requirements: can be used continuously under 200 ℃.
8、壓強壓差要求:能承受壓差15000psi。
8、Pressure differential requirement: can withstand differential pressure of 15,000 psi.
備注:
這些要求,除了500Ⅴ搖表測電阻外,其他我們都無法做,除非用戶具備條件,如扭矩。是裝配時要做的。至于2000h壽命無法檢測。所以這類活我們不好接,他們要試驗,我們只管按要求做涂層,裝配完了滿足絕緣要即可,其他要經過下井試驗。這是件很麻煩的事。上次有二個,搞了三四個月,最后沒有下井,白折騰了!
充分估計難度,這不是新東西,但技術上要求很高,不容易,如果他們有現成方案,我們配合,如果要求我們全包,沒有10~20W的試驗經費就別折騰